Product Overview
The Power End Termination Kit (DPTK) is designed to complete a secure power end termination for heating cable installations. The power end termination must be completed inside a UL/CUL Listed outlet box. Please refer to the DPPK accessory manual, steps 9–13.
This kit includes adhesive-lined heat shrink tubing for bus wire insulation and sealing, plus wire nuts for termination connections.
Product Sheets
Key Benefits
- Clean power-end termination for heating cable installations using adhesive-lined heat shrink sealing.
- Secure sealing method—heat until glue flows from both ends, then pinch and hold to form a tight seal.
- Complete kit content including multiple heat shrink tubes and wire nuts for termination work.
Specifications
-
Rated voltage: 240V
-
Max permissible steady-state current: 30A
-
Max continuous exposure temperature: 85°C
-
Note: connection point temperature may exceed 60°C
Installation Summary
-
Cut and remove the outer jacket 5.5inch (140mm) from the top of the cable (for heating cable without outer jacket, skip this step).
-
Unbraid the braid from the top of the cable. Disperse into two strands, align, and twist.
-
Straighten and twist the two strands into one. Cut and remove the inner insulation 4inch (100mm) from the top of the cable.
-
Shave the black core material from the outside of each bus wire.
-
Peel back the bus wires from the core material and remove the remaining core material.
- Insert the two bus wires into Ø3 (3inch/75mm) black heat shrink tubes individually, then heat evenly side-to-side.
- Slide the Ø12 (2inch/50mm) heat shrink tube into position, heat until glue comes out from both ends, then pinch between the two wires and hold for at least 10 seconds with pliers.